366 lines
14 KiB
Plaintext
366 lines
14 KiB
Plaintext
(export (version D)
|
|
(design
|
|
(source /home/anders/Dropbox/dsox/dsoxlan/dsoxlan.sch)
|
|
(date "Sun 14 Dec 2014 12:08:36 AM EET")
|
|
(tool "Eeschema 0.201412111631+5320~19~ubuntu14.04.1-product"))
|
|
(components
|
|
(comp (ref P1)
|
|
(value CNT-RJ45)
|
|
(footprint awallin:ETH-MAGJACK)
|
|
(libsource (lib conn) (part CNT-RJ45))
|
|
(sheetpath (names /) (tstamps /))
|
|
(tstamp 548C86EB))
|
|
(comp (ref R2)
|
|
(value 220R)
|
|
(footprint Resistors_SMD:R_0805_HandSoldering)
|
|
(libsource (lib device) (part R))
|
|
(sheetpath (names /) (tstamps /))
|
|
(tstamp 548C8821))
|
|
(comp (ref R1)
|
|
(value 220R)
|
|
(footprint Resistors_SMD:R_0805_HandSoldering)
|
|
(libsource (lib device) (part R))
|
|
(sheetpath (names /) (tstamps /))
|
|
(tstamp 548C8849))
|
|
(comp (ref C2)
|
|
(value 1n)
|
|
(footprint Capacitors_SMD:C_0805_HandSoldering)
|
|
(libsource (lib device) (part C))
|
|
(sheetpath (names /) (tstamps /))
|
|
(tstamp 548C8996))
|
|
(comp (ref R3)
|
|
(value 10R)
|
|
(footprint Resistors_SMD:R_0805_HandSoldering)
|
|
(libsource (lib device) (part R))
|
|
(sheetpath (names /) (tstamps /))
|
|
(tstamp 548C8A5B))
|
|
(comp (ref P2)
|
|
(value CONN_02X40)
|
|
(footprint awallin:cardedge_40x2)
|
|
(libsource (lib conn) (part CONN_02X40))
|
|
(sheetpath (names /) (tstamps /))
|
|
(tstamp 548C918C)))
|
|
(libparts
|
|
(libpart (lib device) (part C)
|
|
(description "Condensateur non polarise")
|
|
(footprints
|
|
(fp SM*)
|
|
(fp C?)
|
|
(fp C1-1))
|
|
(fields
|
|
(field (name Reference) C)
|
|
(field (name Value) C))
|
|
(pins
|
|
(pin (num 1) (name ~) (type passive))
|
|
(pin (num 2) (name ~) (type passive))))
|
|
(libpart (lib device) (part R)
|
|
(description Resistance)
|
|
(footprints
|
|
(fp R?)
|
|
(fp SM0603)
|
|
(fp SM0805)
|
|
(fp R?-*)
|
|
(fp SM1206))
|
|
(fields
|
|
(field (name Reference) R)
|
|
(field (name Value) R))
|
|
(pins
|
|
(pin (num 1) (name ~) (type passive))
|
|
(pin (num 2) (name ~) (type passive))))
|
|
(libpart (lib conn) (part CNT-RJ45)
|
|
(description "Symbole general de connexion")
|
|
(fields
|
|
(field (name Reference) P)
|
|
(field (name Value) CNT-RJ45))
|
|
(pins
|
|
(pin (num 1) (name P1) (type passive))
|
|
(pin (num 2) (name P2) (type passive))
|
|
(pin (num 3) (name P3) (type passive))
|
|
(pin (num 4) (name P4) (type passive))
|
|
(pin (num 5) (name P5) (type passive))
|
|
(pin (num 6) (name P6) (type passive))
|
|
(pin (num 7) (name P7) (type passive))
|
|
(pin (num 8) (name P8) (type passive))
|
|
(pin (num 9) (name P9) (type passive))
|
|
(pin (num 10) (name P10) (type passive))
|
|
(pin (num 11) (name P11) (type passive))
|
|
(pin (num 12) (name P12) (type passive))
|
|
(pin (num 13) (name P13) (type passive))
|
|
(pin (num 14) (name P14) (type passive))))
|
|
(libpart (lib conn) (part CONN_02X40)
|
|
(footprints
|
|
(fp Pin_Header_Straight_2X40)
|
|
(fp Pin_Header_Angled_2X40)
|
|
(fp Socket_Strip_Straight_2X40)
|
|
(fp Socket_Strip_Angled_2X40))
|
|
(fields
|
|
(field (name Reference) P)
|
|
(field (name Value) CONN_02X40))
|
|
(pins
|
|
(pin (num 1) (name P1) (type passive))
|
|
(pin (num 2) (name P2) (type passive))
|
|
(pin (num 3) (name P3) (type passive))
|
|
(pin (num 4) (name P4) (type passive))
|
|
(pin (num 5) (name P5) (type passive))
|
|
(pin (num 6) (name P6) (type passive))
|
|
(pin (num 7) (name P7) (type passive))
|
|
(pin (num 8) (name P8) (type passive))
|
|
(pin (num 9) (name P9) (type passive))
|
|
(pin (num 10) (name P10) (type passive))
|
|
(pin (num 11) (name P11) (type passive))
|
|
(pin (num 12) (name P12) (type passive))
|
|
(pin (num 13) (name P13) (type passive))
|
|
(pin (num 14) (name P14) (type passive))
|
|
(pin (num 15) (name P15) (type passive))
|
|
(pin (num 16) (name P16) (type passive))
|
|
(pin (num 17) (name P17) (type passive))
|
|
(pin (num 18) (name P18) (type passive))
|
|
(pin (num 19) (name P19) (type passive))
|
|
(pin (num 20) (name P20) (type passive))
|
|
(pin (num 21) (name P21) (type passive))
|
|
(pin (num 22) (name P22) (type passive))
|
|
(pin (num 23) (name P23) (type passive))
|
|
(pin (num 24) (name P24) (type passive))
|
|
(pin (num 25) (name P25) (type passive))
|
|
(pin (num 26) (name P26) (type passive))
|
|
(pin (num 27) (name P27) (type passive))
|
|
(pin (num 28) (name P28) (type passive))
|
|
(pin (num 29) (name P29) (type passive))
|
|
(pin (num 30) (name P30) (type passive))
|
|
(pin (num 31) (name P31) (type passive))
|
|
(pin (num 32) (name P32) (type passive))
|
|
(pin (num 33) (name P33) (type passive))
|
|
(pin (num 34) (name P34) (type passive))
|
|
(pin (num 35) (name P35) (type passive))
|
|
(pin (num 36) (name P36) (type passive))
|
|
(pin (num 37) (name P37) (type passive))
|
|
(pin (num 38) (name P38) (type passive))
|
|
(pin (num 39) (name P39) (type passive))
|
|
(pin (num 40) (name P40) (type passive))
|
|
(pin (num 41) (name P41) (type passive))
|
|
(pin (num 42) (name P42) (type passive))
|
|
(pin (num 43) (name P43) (type passive))
|
|
(pin (num 44) (name P44) (type passive))
|
|
(pin (num 45) (name P45) (type passive))
|
|
(pin (num 46) (name P46) (type passive))
|
|
(pin (num 47) (name P47) (type passive))
|
|
(pin (num 48) (name P48) (type passive))
|
|
(pin (num 49) (name P49) (type passive))
|
|
(pin (num 50) (name P50) (type passive))
|
|
(pin (num 51) (name P51) (type passive))
|
|
(pin (num 52) (name P52) (type passive))
|
|
(pin (num 53) (name P53) (type passive))
|
|
(pin (num 54) (name P54) (type passive))
|
|
(pin (num 55) (name P55) (type passive))
|
|
(pin (num 56) (name P56) (type passive))
|
|
(pin (num 57) (name P57) (type passive))
|
|
(pin (num 58) (name P58) (type passive))
|
|
(pin (num 59) (name P59) (type passive))
|
|
(pin (num 60) (name P60) (type passive))
|
|
(pin (num 61) (name P61) (type passive))
|
|
(pin (num 62) (name P62) (type passive))
|
|
(pin (num 63) (name P63) (type passive))
|
|
(pin (num 64) (name P64) (type passive))
|
|
(pin (num 65) (name P65) (type passive))
|
|
(pin (num 66) (name P66) (type passive))
|
|
(pin (num 67) (name P67) (type passive))
|
|
(pin (num 68) (name P68) (type passive))
|
|
(pin (num 69) (name P69) (type passive))
|
|
(pin (num 70) (name P70) (type passive))
|
|
(pin (num 71) (name P71) (type passive))
|
|
(pin (num 72) (name P72) (type passive))
|
|
(pin (num 73) (name P73) (type passive))
|
|
(pin (num 74) (name P74) (type passive))
|
|
(pin (num 75) (name P75) (type passive))
|
|
(pin (num 76) (name P76) (type passive))
|
|
(pin (num 77) (name P77) (type passive))
|
|
(pin (num 78) (name P78) (type passive))
|
|
(pin (num 79) (name P79) (type passive))
|
|
(pin (num 80) (name P80) (type passive)))))
|
|
(libraries
|
|
(library (logical device)
|
|
(uri /usr/share/kicad/library/device.lib))
|
|
(library (logical conn)
|
|
(uri /usr/share/kicad/library/conn.lib)))
|
|
(nets
|
|
(net (code 1) (name "Net-(P2-Pad67)")
|
|
(node (ref P2) (pin 67)))
|
|
(net (code 2) (name "Net-(P2-Pad26)")
|
|
(node (ref P2) (pin 26)))
|
|
(net (code 3) (name "Net-(P2-Pad36)")
|
|
(node (ref P2) (pin 36)))
|
|
(net (code 4) (name "Net-(P2-Pad46)")
|
|
(node (ref P2) (pin 46)))
|
|
(net (code 5) (name "Net-(P2-Pad56)")
|
|
(node (ref P2) (pin 56)))
|
|
(net (code 6) (name "Net-(P2-Pad66)")
|
|
(node (ref P2) (pin 66)))
|
|
(net (code 7) (name "Net-(P2-Pad76)")
|
|
(node (ref P2) (pin 76)))
|
|
(net (code 8) (name "Net-(P2-Pad17)")
|
|
(node (ref P2) (pin 17)))
|
|
(net (code 9) (name "Net-(P2-Pad27)")
|
|
(node (ref P2) (pin 27)))
|
|
(net (code 10) (name "Net-(P2-Pad37)")
|
|
(node (ref P2) (pin 37)))
|
|
(net (code 11) (name "Net-(P2-Pad16)")
|
|
(node (ref P2) (pin 16)))
|
|
(net (code 12) (name "Net-(P2-Pad77)")
|
|
(node (ref P2) (pin 77)))
|
|
(net (code 13) (name "Net-(P2-Pad18)")
|
|
(node (ref P2) (pin 18)))
|
|
(net (code 14) (name "Net-(P2-Pad28)")
|
|
(node (ref P2) (pin 28)))
|
|
(net (code 15) (name "Net-(P2-Pad38)")
|
|
(node (ref P2) (pin 38)))
|
|
(net (code 16) (name +3V3)
|
|
(node (ref R3) (pin 1))
|
|
(node (ref P2) (pin 50))
|
|
(node (ref R2) (pin 1))
|
|
(node (ref P2) (pin 48))
|
|
(node (ref R1) (pin 1)))
|
|
(net (code 17) (name "Net-(P2-Pad58)")
|
|
(node (ref P2) (pin 58)))
|
|
(net (code 18) (name "Net-(P2-Pad68)")
|
|
(node (ref P2) (pin 68)))
|
|
(net (code 19) (name "Net-(P2-Pad78)")
|
|
(node (ref P2) (pin 80))
|
|
(node (ref P2) (pin 78)))
|
|
(net (code 20) (name "Net-(P2-Pad19)")
|
|
(node (ref P2) (pin 19)))
|
|
(net (code 21) (name "Net-(P2-Pad29)")
|
|
(node (ref P2) (pin 29)))
|
|
(net (code 22) (name "Net-(P2-Pad44)")
|
|
(node (ref P2) (pin 44)))
|
|
(net (code 23) (name "Net-(P2-Pad13)")
|
|
(node (ref P2) (pin 13)))
|
|
(net (code 24) (name "Net-(P2-Pad23)")
|
|
(node (ref P2) (pin 23)))
|
|
(net (code 25) (name "Net-(P2-Pad33)")
|
|
(node (ref P2) (pin 33)))
|
|
(net (code 26) (name LED2)
|
|
(node (ref P1) (pin 14))
|
|
(node (ref P2) (pin 43)))
|
|
(net (code 27) (name LED1)
|
|
(node (ref P2) (pin 63))
|
|
(node (ref P1) (pin 12)))
|
|
(net (code 28) (name "Net-(P2-Pad73)")
|
|
(node (ref P2) (pin 73)))
|
|
(net (code 29) (name "Net-(P2-Pad14)")
|
|
(node (ref P2) (pin 14)))
|
|
(net (code 30) (name "Net-(P2-Pad24)")
|
|
(node (ref P2) (pin 24)))
|
|
(net (code 31) (name "Net-(P2-Pad34)")
|
|
(node (ref P2) (pin 34)))
|
|
(net (code 32) (name "Net-(P2-Pad39)")
|
|
(node (ref P2) (pin 39)))
|
|
(net (code 33) (name "Net-(P2-Pad64)")
|
|
(node (ref P2) (pin 64)))
|
|
(net (code 34) (name "Net-(P2-Pad74)")
|
|
(node (ref P2) (pin 74)))
|
|
(net (code 35) (name "Net-(P2-Pad15)")
|
|
(node (ref P2) (pin 15)))
|
|
(net (code 36) (name "Net-(P2-Pad25)")
|
|
(node (ref P2) (pin 25)))
|
|
(net (code 37) (name "Net-(P2-Pad35)")
|
|
(node (ref P2) (pin 35)))
|
|
(net (code 38) (name "Net-(P2-Pad45)")
|
|
(node (ref P2) (pin 45)))
|
|
(net (code 39) (name "Net-(P2-Pad65)")
|
|
(node (ref P2) (pin 65)))
|
|
(net (code 40) (name "Net-(P2-Pad75)")
|
|
(node (ref P2) (pin 75)))
|
|
(net (code 41) (name TX+)
|
|
(node (ref P1) (pin 5))
|
|
(node (ref P2) (pin 47)))
|
|
(net (code 42) (name TX-)
|
|
(node (ref P1) (pin 6))
|
|
(node (ref P2) (pin 49)))
|
|
(net (code 43) (name RX+)
|
|
(node (ref P1) (pin 1))
|
|
(node (ref P2) (pin 55)))
|
|
(net (code 44) (name RX-)
|
|
(node (ref P2) (pin 57))
|
|
(node (ref P1) (pin 2)))
|
|
(net (code 45) (name GND)
|
|
(node (ref P2) (pin 51))
|
|
(node (ref P2) (pin 52))
|
|
(node (ref P1) (pin 8))
|
|
(node (ref P1) (pin 9))
|
|
(node (ref P1) (pin 10))
|
|
(node (ref C2) (pin 1))
|
|
(node (ref P2) (pin 53))
|
|
(node (ref P2) (pin 54)))
|
|
(net (code 46) (name "Net-(P2-Pad59)")
|
|
(node (ref P2) (pin 59)))
|
|
(net (code 47) (name "Net-(P2-Pad69)")
|
|
(node (ref P2) (pin 69)))
|
|
(net (code 48) (name "Net-(P2-Pad79)")
|
|
(node (ref P2) (pin 79)))
|
|
(net (code 49) (name "Net-(P2-Pad72)")
|
|
(node (ref P2) (pin 72)))
|
|
(net (code 50) (name "Net-(P1-Pad13)")
|
|
(node (ref R2) (pin 2))
|
|
(node (ref P1) (pin 13)))
|
|
(net (code 51) (name "Net-(P1-Pad11)")
|
|
(node (ref P1) (pin 11))
|
|
(node (ref R1) (pin 2)))
|
|
(net (code 52) (name "Net-(P1-Pad7)")
|
|
(node (ref P1) (pin 7)))
|
|
(net (code 53) (name "Net-(C2-Pad2)")
|
|
(node (ref P1) (pin 4))
|
|
(node (ref P1) (pin 3))
|
|
(node (ref C2) (pin 2))
|
|
(node (ref R3) (pin 2)))
|
|
(net (code 54) (name "Net-(P2-Pad31)")
|
|
(node (ref P2) (pin 31)))
|
|
(net (code 55) (name "Net-(P2-Pad9)")
|
|
(node (ref P2) (pin 9)))
|
|
(net (code 56) (name "Net-(P2-Pad10)")
|
|
(node (ref P2) (pin 10)))
|
|
(net (code 57) (name "Net-(P2-Pad20)")
|
|
(node (ref P2) (pin 20)))
|
|
(net (code 58) (name "Net-(P2-Pad30)")
|
|
(node (ref P2) (pin 30)))
|
|
(net (code 59) (name "Net-(P2-Pad40)")
|
|
(node (ref P2) (pin 40)))
|
|
(net (code 60) (name "Net-(P2-Pad60)")
|
|
(node (ref P2) (pin 60)))
|
|
(net (code 61) (name "Net-(P2-Pad70)")
|
|
(node (ref P2) (pin 70)))
|
|
(net (code 62) (name "Net-(P2-Pad11)")
|
|
(node (ref P2) (pin 11)))
|
|
(net (code 63) (name "Net-(P2-Pad21)")
|
|
(node (ref P2) (pin 21)))
|
|
(net (code 64) (name "Net-(P2-Pad8)")
|
|
(node (ref P2) (pin 8)))
|
|
(net (code 65) (name "Net-(P2-Pad41)")
|
|
(node (ref P2) (pin 41)))
|
|
(net (code 66) (name "Net-(P2-Pad61)")
|
|
(node (ref P2) (pin 61)))
|
|
(net (code 67) (name "Net-(P2-Pad71)")
|
|
(node (ref P2) (pin 71)))
|
|
(net (code 68) (name "Net-(P2-Pad12)")
|
|
(node (ref P2) (pin 12)))
|
|
(net (code 69) (name "Net-(P2-Pad22)")
|
|
(node (ref P2) (pin 22)))
|
|
(net (code 70) (name "Net-(P2-Pad32)")
|
|
(node (ref P2) (pin 32)))
|
|
(net (code 71) (name "Net-(P2-Pad42)")
|
|
(node (ref P2) (pin 42)))
|
|
(net (code 72) (name "Net-(P2-Pad62)")
|
|
(node (ref P2) (pin 62)))
|
|
(net (code 73) (name "Net-(P2-Pad1)")
|
|
(node (ref P2) (pin 1)))
|
|
(net (code 74) (name "Net-(P2-Pad2)")
|
|
(node (ref P2) (pin 2)))
|
|
(net (code 75) (name "Net-(P2-Pad3)")
|
|
(node (ref P2) (pin 3)))
|
|
(net (code 76) (name "Net-(P2-Pad4)")
|
|
(node (ref P2) (pin 4)))
|
|
(net (code 77) (name "Net-(P2-Pad5)")
|
|
(node (ref P2) (pin 5)))
|
|
(net (code 78) (name "Net-(P2-Pad6)")
|
|
(node (ref P2) (pin 6)))
|
|
(net (code 79) (name "Net-(P2-Pad7)")
|
|
(node (ref P2) (pin 7))))) |