If config-file is set to the filepath of a XML file, such as is
generated by eBUS Player, it will be used to restore configuration
to the device and stream. By default, the device and stream will be
connected using the information from the config-file. Set
config-file-connect=false to connect to the camera using other element
properties, and then apply the configuration changes from the
config-file.
For example, a Mono8 642x482 would have failed to work, as GStreamer
expects the stride to be a multiple of 4-bytes, that is 644 bytes in
this example, while Pleora doesn't do this alignment. This incurs a copy
unfortunately, and there might be a way with memory meta to avoid this,
however eventually most elements will need to have the data 4-byte
aligned.